Egyéb infó
150W Constant Current Electronic Load 60V 10A Battery Discharge Capacity TesterDescription:This is a very convenient electronic load, the use of two completely independent chip 18-bit ADC, 15ppm benchmark voltage, makes the electronic load has very high accuracy, with 1602 LCD display, display the information in a comprehensive, spike any one with the monolithic integrated circuit built-in AD digital load electronic display sampling or battery capacity tester, configuration CPU fan 9 cm, very quiet, maximum cargo capacity reached 150 W, up to a maximum voltage of 60 V, 10a, with temperature display and supports the discharge as a setting voltage can for all types of charging power source / aging tests etc. can also be of various cellular / of the battery discharge capacity test and parameters to support the correct user is the DIY users, the best choiceFeatures:
Supply voltage: DC12V ± 5%
Charging mode: constant current load
Load voltage: 0.5-60 V
Load current: -10A
Maximum power: 150 W
Reading accuracy voltage: ± (0.1% 0.05% FS)
Current reading accuracy: ± (0.2% 0.1% FS)
Constant current precision: Current display accuracy 1d
Index of noise: 25dD (A)
Basic format: 10 x 14 x 7cm
Instructions:
1. power adapter: DC12V, with particular attention to the load and power supply must be two independent power supplys.
2. That the screen displays Welcome when started means that the device is good.
3. According to the "set" key to move the cursor, and the cursor position for addition and subtraction operation. When the position of the cursor is in the "I" or "V" according to the 'addition and subtraction of voltage switching and current settings
4. To test the power of the connection, pay attention to the positive and negative, try to avoid the reverse gear.
5. The "start" button is to start / stop electronic load, meanwhile the screen display "ON" or "DI".
6. Often push on the "start" button for 1 second or longer to eliminate the value of AH and time as well as to stop the electronic load (if it is open).
7. On default state, the information displayed on the left bottom are power and temperature and the automatic switching time, two seconds a switch, press and hold the & ldquo; set-up & rdquo; key and press the & ldquo; & Rdquo; you can manually switch the display, each from a & ldquo; & Rdquo; spend (always keep & ldquo; create & rdquo; key) switch, fixed switch the display of information, no longer automatically change and the need to open again automatically switch press and hold the & ldquo; Creation & rdquo; key and press the & ldquo; reduction & rdquo; right corner of the screen display & ldquo; has automatic open switch said
8. all of the above settings will automatically be saved after power off, power parameters are again on the power down before the parameters, but the electronic load, no matter whether the power is off, is needed to manually open.
9. After a continuous operation load of the maximum power, the ambient temperature will be high and users should reduce the operating power. If the temperature of the heat sink has reached 87â„, the load is automatically reduces the power;if the temperature continues to rise, it will continue to reduce the power, when the internal temperature reaches 91â„, it will stop. It needs to open manually , after cooling.
10. The load current will be in accordance with the input voltage automatically make adjustments, such as the set 10a, if the input voltage is 20 V, will be the actual current is changed to 150 W / 20 V = 7.5A (display sets the still sets the current is up to 10th)
11. In need of statistical AH and time before, remember to clear the machine is the default setting has been accumulated, it will not be automatically deleted, it can only be removed manually.Package Include:1 x 150W Constant Current Electronic Load 60V 10A Battery Discharge Capacity TesterPayment
Shipping
RefundPaymentWe acce
201858122551 - ali110 (281)